buy a Multidata WR3 Zenner in United States

No supplier Zenner from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Multidata WR3
Manufacturer
Country
Germany
Сalculator
Multidata WR3
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
10 years
Monthly archive
18 months
Daily archive
460 days
Archive by hours
2200 hours
Downtime
does not register
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
120 °C
Temperature difference Min
3 °C
Temperature sensor
Pt500
Length of the sensor
45 / 105 mm
Tmax
150 °C
Tmin
1 °C
Standard cable length
3 m
Maximum cable length
5, 10 m
Flow sensor
Sonar
Type
ultrasonic
Dynamic range
1:100
Standard cable length
3 m
Maximum cable length
5, 10 m
PN
16, 25
Tmax
130 °C
Tmin
5 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
25G 3.5
6.0
-

-

0.035

0.060

7.0

12.0

6.5

19

260

260

not required
not required
add your price

40G 10.0
-

0.10

20.0

12

300

not required
not required
add your price
25F 3.5
6.0
-

-

0.035

0.060

7.0

12.0

6.5

19

260

260

not required
not required
add your price

40F 10
-

0.100

20.0

12

300

not required
not required
add your price
50F 15
-

0.15

30.0

12

270

not required
not required
add your price
65F 25
-

0.25

50.0

7.0

300

not required
not required
add your price
80F 40
-

0.40

80

12

300

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
1 487 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog