Multical 401 Kamstrup
Heat meter

production of discontinued

calculation and selection
92 % - model rating
Drawing Multical 401 Kamstrup Heat meter Design Multical 401 Kamstrup Heat meter Scheme Multical 401 Kamstrup Heat meter
Технический паспорт
Характеристикт датчиков температуры Pt500
Model
Multical 401
Manufacturer
Country
Denmark
Сalculator
Multical 401
Accuracy class according to EN 1434-1
2
Construction
single-piece construction
Power supply
from power element (battery)
Yearly archive
option
Monthly archive
24 months
Daily archive
option
Archive by hours
option
Downtime
does not register
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
150 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
65 / 90 mm
Tmax
160 °C
Tmin
10 °C
Standard cable length
2.0 m
Maximum cable length
3.0 m
Flow sensor
Ultraflow
Type
ultrasonic
Dynamic range
1:100
Standard cable length
1.0 m
Maximum cable length
1.0 m
PN
25 / 16
Tmax
130 °C
Tmin
15 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
-

-

0.006

0.015

1.2

3.0

4.0

25

110

110

not required
not required
production of discontinued

20 G 1.5
1.5
1.5
2.5
2.5
-

-

-

-

-

0.015

0.015

0.015

0.025

0.025

3.0

3.0

3.0

5.0

5.0

25

25

25

4.0

4.0

165

130

190

130

190

not required
not required
production of discontinued




25 G 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

16

260

260

not required
not required
production of discontinued

25 FL 6.0
-

0.060

12

16

260

not required
not required
production of discontinued
40 G 10
-

0.10

20

7.0

300

not required
not required
production of discontinued
40 FL 10
-

0.10

20

7.0

300

not required
not required
production of discontinued
50 FL 15
-

0.15

30

15

270

not required
not required
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
Water flow rate
m³/h
add your product to the catalog

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website
1 487 visitors yesterday
visitors per month
23 501 from United States
73 417 from all countries
add your company to the catalog