PolluTherm Sensus
Heat meter

production of discontinued

calculation and selection
67 % - model rating
Drawing PolluTherm Sensus Heat meter Design PolluTherm Sensus Heat meter Scheme PolluTherm Sensus Heat meter
Паспорт
Сертифікат відповідності
Сертифікат затвердження
Model
PolluTherm
Manufacturer
Sensus
Country
Slovakia
Сalculator
PolluTherm
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
16 months
Daily archive
512 days
Archive by hours
option
Downtime
registers
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
145 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
100 mm
Tmax
150 °C
Tmin
1.0 °C
Standard cable length
3.0 m
Maximum cable length
23 m
Flow sensor
PolluFlow
Type
ultrasonic
Dynamic range
1:100
Standard cable length
5.0 m
Maximum cable length
? m
PN
25 / 16
Tmax
150 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
-

-

0.006

0.015

1.2

3.0

20

7.0

110

110

not required
not required
production of discontinued

20 G 0.60
1.5
2.5
2.5
-

-

-

-

0.006

0.015

0.025

0.025

1.2

3.0

5.0

5.0

20

7.0

20

20

190

190

130

190

not required
not required
production of discontinued



20 FL 0.60
1.5
2.5
-

-

-

0.006

0.015

0.025

1.2

3.0

5.0

20

7.0

20

190

190

190

3DN
1DN
production of discontinued


25 G 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

8.0

260

260

not required
not required
production of discontinued

25 FL 3.5
6.0
-

-

0.035

0.060

7.0

12

6.0

8.0

260

260

3DN
1DN
production of discontinued

40 G 10
-

0.10

20

4.0

300

not required
not required
production of discontinued
40 FL 10
-

0.10

20

4.0

300

3DN
1DN
production of discontinued
50 FL 15
-

0.15

30

10

270

3DN
1DN
production of discontinued
65 FL 25
-

0.25

50

7.0

300

3DN
1DN
production of discontinued
80 FL 40
-

0.40

80

1.5

300

3DN
1DN
production of discontinued
100 FL 60
-

0.60

120

1.0

360

3DN
1DN
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter
m³/h

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website

about us

our library

United States

add your company to the catalog