Model
Multical UF Ultraflow 54
Manufacturer
Kamstrup
Country
Denmark
Сalculator
Multical 601
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
15 years
Monthly archive
36 months
Daily archive
460 days
Archive by hours
1392 hours
Downtime
registers
Error registration
registers
Data retrieval
optical interface
Temperature difference Max
170 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt500
Length of the sensor
27,5 / 47 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
1,5/3/5 m
Maximum cable length
3/10 m
Flow sensor
ULTRAFLOW 54
Type
ultrasonic
Dynamic range
1:100
Standard cable length
2,5 / 5,0 m
Maximum cable length
10 m
PN
25 / 16
Tmax
130 / 150
Tmin
15 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 G 0.60
1.5
1.5
-

-

-

0.006

0.015

0.015

1.2

3.0

3.0

4.0

22

22

110

110

165

5DN
not required
production of discontinued


20 G 0.60
1.5
1.5
2.5
-

-

-

-

0.006

0.015

0.015

0.025

1.2

3.0

3.0

5.0

4.0

0.22

0.22

3.0

130

130

190

190

5DN
not required
production of discontinued



20 FL 1.5
2.5
-

-

0.015

0.025

3.0

5.0

0.22

3.0

190

190

5DN
not required
production of discontinued

25 G 3.5
6.0
-

-

0.035

0.060

7.0

12

7.0

20

260

260

5DN
not required
production of discontinued

25 FL 3.5
6.0
-

-

0.035

0.060

7.0

12

7.0

20

260

260

5DN
not required
production of discontinued

40 G 10
-

0.10

20

6.0

300

5DN
not required
production of discontinued
40 FL 10
-

0.10

20

6.0

300

5DN
not required
production of discontinued
50 FL 15
-

0.15

30

14

270

5DN
not required
production of discontinued
65 FL 25
-

0.25

50

6.0

300

5DN
not required
production of discontinued
80 FL 40
-

0.40

80

5.0

300

5DN
not required
production of discontinued
100 60
100
-

-

0.60

1.0

120

200

3.0

7.0

360

360

10DN
3DN
production of discontinued

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter