Microclima U Maddalena
Heat meter

calculation and selection
77 % - model rating
Drawing Microclima U Maddalena Heat meter Scheme Microclima U Maddalena Heat meter
Data sheet
Installation guide IT/EN

buy a Microclima U Maddalena in United States

No supplier Maddalena from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Microclima U
Manufacturer
Maddalena
Country
Italy
Сalculator
Microclima U
Accuracy class according to EN 1434-1
2
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
15 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
100 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt1000
Length of the sensor
27.5 / 75 mm
Tmax
100 °C
Tmin
5.0 °C
Standard cable length
1.5 m
Maximum cable length
3.0 / 6.0 m
Flow sensor
Microclima U
Type
ultrasonic
Dynamic range
1:100
Standard cable length
0.85 m
Maximum cable length
2.9 m
PN
16
Tmax
90 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.012

0.012

1.2

3.0

3.0

21

110

110

not required
not required
add your price

20 1.5
2.5
3.5
-

-

-

0.012

0.025

0.028

3.0

5.0

7.0

4.0

12

21

130

130

130

not required
not required
add your price


25 3.5
6.0
-

-

0.028

0.060

7.0

12

21

20

150

150

not required
not required
add your price

40 10
-

0.10

20

11

200

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter
m³/h

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website

about us

our library

United States

add your company to the catalog