Sensostar U Engelmann - Heat meter

Sensostar U Engelmann
Heat meter

calculation and selection
91 % - model rating
Drawing Sensostar U Engelmann Heat meter Scheme Sensostar U Engelmann Heat meter
Data sheet DE
Manual DE

buy a Sensostar U Engelmann in Land of dreams

No supplier Engelmann from Land of dreams is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Sensostar U
Manufacturer
Engelmann
Country
Germany
Сalculator
Sensostar U
Accuracy class according to EN 1434-1
2.0
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
15 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
100 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt1000
Length of the sensor
27.5 / 38 mm
Tmax
150 °C
Tmin
0 °C
Standard cable length
1.5 m
Maximum cable length
3.0 / 6.0 m
Flow sensor
Sensostar U
Type
ultrasonic
Dynamic range
1:100
Standard cable length
0.85 m
Maximum cable length
2.9 m
PN
16
Tmax
130 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.006

0.015

1.2

3.0

3.0

9.0

110

110

not required
not required
add your price

20 0.60
1.5
2.5
3.5
-

-

-

-

0.006

0.015

0.025

0.035

1.2

3.0

5.0

7.0

2.0

2.0

5.0

9.0

190

190

190

190

not required
not required
add your price



25 2.5
3.5
6.0
-

-

-

0.025

0.035

0.060

5.0

7.0

12

5.0

9.0

8.0

260

260

260

not required
not required
add your price


40 10
0.10

20

4.0

300

not required
not required
add your price

DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter
m³/h

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in Land of dreams. Join the community and you will receive emails with requests for work in Land of dreams from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website

about us

our library

Land of dreams

add your company to the catalog