DN mm |
Qn m³/h |
Qt m³/h |
Qmin m³/h |
Qmax m³/h |
dP kPa |
L mm |
DN 'Up' DN 'Down' |
price |
---|---|---|---|---|---|---|---|---|
15 | 0.60 1.0 1.5 |
0.048 0.080 0.12 |
0.012 0.020 0.030 |
1.2 2.0 3.0 |
20 30 20 |
110 110 110 |
see descr. see descr. |
production of discontinued |
20 | 1.5 2.5 |
0.12 0.20 |
0.030 0.050 |
3.0 5.0 |
20 20 |
130 130 |
see descr. see descr. |
production of discontinued |
25 | 3.0 |
0.35 |
0.14 |
7.0 |
20 |
260 |
see descr. see descr. |
production of discontinued |
32 | 6.0 |
0.60 |
0.24 |
12 |
30 |
260 |
see descr. see descr. |
production of discontinued |
40 | 10 |
1.0 |
0.30 |
20 |
25 |
300 |
see descr. see descr. |
production of discontinued |
DN - nominal diameter (FL, G - flanged and threaded execution), mm.
Qn - nominal flow rate, m³/h.
Qt - transitional flow rate, m³/h.
Qmin - minimum flow rate, m³/h.
Qmax - maximum flow rate, m³/h.
dP - pressure loss across the flow meter at nominal flow rate, kPa.
L - length along the pipeline axis, mm.
DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.
DN 'Down' - also downstream of the flow meter, mm.