Model
Solida
Manufacturer
Country
Italy
Allowable working fluids
Water
Firebox material
cast iron
Efficiency of a solid fuel boiler
75 %
Permissible fuel type
Coal, Wood,
Maximum water temperature at the boiler outlet
90 °C
Minimum water temperature at boiler inlet
50 °C
Nominal water pressure in the boiler
0.40 MPa

technical
specifications
price

model N
kW
Vf
Тst
mm
Vw
l
Ps
Pa
ds
mm
DN
mm
m
kg
H:W:D
mm
price
Solida 3 16 0.017 - 23 8 147 50 175 1082
469
355
production of discontinued
Solida 4 21 0.026 - 27 10 147 50 210 1082
469
455
production of discontinued
Solida 5 26 0.034 - 31 12 147 50 245 1082
469
555
production of discontinued
Solida 6 30 0.043 - 35 13 147 50 280 1082
469
655
production of discontinued
Solida 7 35 0.051 - 39 15 147 50 315 1082
469
755
production of discontinued
Solida 8 40 0.060 - 43 18 147 50 350 1082
469
855
production of discontinued

N - thermal capacity of solid fuel boiler, kW. Usually specified by the manufacturer for burning coal of the 'Anthracite' grade.

Vf - maximum volume of one-time fuel loading, m³.

Тst - thickness of the steel (cast iron) wall of the combustion chamber, mm.

Vw - volume of water in the boiler, l.

Ps - minimum vacuum in the boiler chimney, Pa.

ds - diameter of the chimney flange at the boiler outlet, mm.

DN - nominal diameter of connecting flanges, at the inlet and outlet of the solid fuel boiler, mm

m - weight of the boiler, kg.

H:W:D - overall dimensions of the boiler, Height : Width : Depth, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
boiler power
kW

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website

about us

our library

United States

add your company to the catalog