Superstatic 749 Sontex
Compact heat meter

calculation and selection
66 % - model rating
Drawing Superstatic 749 Sontex Compact heat meter Design Superstatic 749 Sontex Compact heat meter Scheme Superstatic 749 Sontex Compact heat meter
Installation guide
Data sheet
Instruction for use

buy a Superstatic 749 Sontex in United States

No supplier Sontex from United States is registered in our catalog
Register and our visitors will become your customers

[0] priority

add company

Model
Superstatic 749
Manufacturer
Sontex
Country
Switzerland
Сalculator
Superstatic 749
Accuracy class according to EN 1434-1
2.0
Construction
modular construction
Power supply
from power element (battery)
Yearly archive
not provided
Monthly archive
18 months
Daily archive
not provided
Archive by hours
not provided
Downtime
registers
Error registration
registers
Data retrieval
M-Bus
Temperature difference Max
75 °C
Temperature difference Min
3.0 °C
Temperature sensor
Pt1000
Length of the sensor
31 mm
Tmax
90 °C
Tmin
0 °C
Standard cable length
1.5 m
Maximum cable length
1.5 m
Flow sensor
Superstatic 749
Type
resonant
Dynamic range
1:100
Standard cable length
0.60 m
Maximum cable length
0.60 m
PN
16
Tmax
90 °C
Tmin
5.0 °C

technical
specifications
price

DN
mm
Qn
m³/h
Qt
m³/h
Qmin
m³/h
Qmax
m³/h
dP
kPa
L
mm
DN 'Up'
DN 'Down'
price
15 0.60
1.5
-

-

0.006

0.015

1.2

3.0

19

20

110

110

not required
not required
add your price

20 1.5
2.5
1.5
2.5
-

-

-

-

0.015

0.025

0.015

0.025

3.0

5.0

3.0

5.0

20

19

20

19

130

130

190

190

not required
not required
add your price



DN - nominal diameter (FL, G - flanged and threaded execution), mm.

Qn - nominal flow rate, m³/h.

Qt - transitional flow rate, m³/h.

Qmin - minimum flow rate, m³/h.

Qmax - maximum flow rate, m³/h.

dP - pressure loss across the flow meter at nominal flow rate, kPa.

L - length along the pipeline axis, mm.

DN 'Up' - the minimum required length of straight pipe upstream of the flowmeter necessary to ensure measurement accuracy, in nominal diameters, mm.

DN 'Down' - also downstream of the flow meter, mm.

question : comment : feedback

where to notify about the reply. not published anywhere
water flow rate
through the heat meter
m³/h

community of experts

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in United States. Join the community and you will receive emails with requests for work in United States from our visitors.

design
installation
service
heating
water supply
conditioning
dealers
advertising on the website

about us

our library

United States